AAIB investigation to Letov LK-2M Sluka, G-MZBF
Partial loss of control due to disconnection of right aileron cable turnbuckle, 1nm South of Kernan Airfield, Tandragee, County Armagh, 6 March 2022.
Summary:
At approximately 600 ft agl, during final approach to Kernan Airfield, the pilot felt a sudden release of pressure in the control column and a loss of roll control. He carried out a forced landing in a field immediately below, striking a hedge just before touchdown.
The cause of the accident was loss of right aileron control, due to a turnbuckle becoming disconnected from the right aileron cable due to a lack of secondary locking.
Download report: