Product Recall: 3M™ Versaflo™ A2B2E2K1HgP Filter, TR-6580E (2212-0126)

Product recall for 3M™ Versaflo™ A2B2E2K1HgP Filter, TR-6580E presenting a risk to health.

Summary

Product: 3M™ Versaflo™ A2B2E2K1HgP Filter, TR-6580E - suitable for storage up to 50 degrees C and manufactured prior to November 2022.

Hazard: Internal quality testing of TR-6580E filters, labelled as suitable for storage between -30⁰C /+50⁰C, demonstrated that this product does not meet the performance requirements of the relevant standard, when subject to the temperature range described in the storage instructions.

Corrective action: Recall of the product from end users. The product has been withdrawn from the market.

Product information

Type Personal protective equipment (PPE) - Respirator Filter
Product identifiers A2B2E2K1HgP Filter, TR-6580E
Country of Origin Canada
Product Description TR-6580E filters are used with the 3M™ Versaflo™ TR-600 and TR-800 Powered Air Purifying Respirators
Product Report and Image Link to Product Image and PDF

Hazard

Internal quality testing of TR-6580E filters, labelled as suitable for storage between -30⁰C /+50⁰C, demonstrated that this product does not meet the performance requirements of the relevant standard, when subject to the temperature range described in the storage instructions (intended conditions of use):

Therefore, it cannot be assured that these products meet the stated performance standards, and may have reduced breakthrough times for the gases and vapours that the filter is certified to protect against. This is particularly significant when the product is being used to protect against mercury vapour (Hg), as mercury vapour does not have clear warning properties should breakthrough occur.

Corrective action

Recall of the product from end users. This recall does not affect products manufactured after November 2022, which state suitable storage conditions to be between -30 and +40 degrees)

The product has been withdrawn from the market.

End Users should contact 3M Sales Representatives if they have any queries.

Additional information

PSD case number: 2212-0126

Notified by: Health and Safety Executive.

Updates to this page

Published 9 February 2023