Product Recall: Fluke 8x V Series Digital Multimeters (DMM) (2301-0135)
Product recall for Fluke 8x V Series Digital Multimeters (DMM) presenting a high risk of electric shock.
Summary
Product: Fluke 8x V Series Digital Multimeters (DMM)
Hazard: Some products may have an intermittent electrical connection in the COM terminal which may cause an operator to incorrectly assess a hazardous electrical installation as being disconnected/safe to touch.
Corrective action: The importer has withdrawn the product from the market and informed all distributors to stop sale and return any affected. (For more information please see below).
Product information
Type | Electrical appliances and equipment – Digital Multimeters |
---|---|
Brand | Fluke |
Model/type | Within the Fluke 8x V Series, the following models: Fluke 87V, Fluke 87V MAX, Fluke 83V, Fluke 88V |
Serial numbers | The affected serial numbers are as follows: All Fluke 83V, 87V, 87V MAX or Fluke 88 V models with a serial number between 46280001 and 55370001 (both included). Users can check if they have one of the affected appliances on the back of the appliances. |
Country of Origin | United States |
Product Description | The product is used to make electrical measurements and tests including AC and DC voltage, temperature (thermocouple), resistance, continuity, capacitance, AC and DC current by professional operators |
Product Report and Image |
Hazard
Some products may have an intermittent electrical connection in the COM terminal which may cause an operator to incorrectly assess a hazardous electrical installation as being disconnected/safe to touch.
This incorrect assessment could result in electric shock/electrocution/burns due to arc flash if contact is made with the installation conductors.
Corrective action
The importer has withdrawn the affected product from the market and informed all distributors to stop sale and return any affected products.
The importer has informed and contacted distributors/end customers with information related to the potential safety risk and provided instructions to perform a simple test and return the DMMs for repair, free of charge.
The importer has issued a safety notice on its website to all end customers who have purchased the products. For more information, please access the Fluke website: https://www.fluke.com/en-us/support/safety-notices/8x-v-safety-notice
Additional information
PSD case number: 2301-0135
Notified by: Health and Safety Executive