Product Safety Report: Puhui IR Preheating Plate (T-8280) (2207-0049)

Product Safety Report for Puhui IR Preheating Plate (Model: T-8280) presenting a serious risk of electric shock as the appliance was inadequately earthed and the clamping means was not adequately secured against accidental loosening.

Summary

Product: Puhui IR Preheating Plate, T-8280

Hazard: The product presents a serious risk of electric shock as the appliance was inadequately earthed and the clamping means was not adequately secured against accidental loosening.

Corrective action: The import has been rejected at the border.

Product information

Type Electrical appliances and equipment – Preheating plate
Batch No RVG3355-220228-0009-565
Other product identifiers G3355-T8280JRQ000000001V2, 6/16, GBLFD-GC0091-73, IN30
Product description Blue and yellow Infrared IC pre-heat plate with metal bars
Country of Origin China
Product Report and Image Link to product image and PDF

Hazard

The product presents a serious risk of electric shock as the appliance was inadequately earthed and the clamping means was not adequately secured against accidental loosening. The cord set did not comply with BSEN 60799 and The plug on this sample failed to comply with BS1363-1 as the dimensions of the sleeved parts of the pins differed from the metal parts of the pins. This resulted in a distinct step between the two. This could cause damage to the socket and undue wear and tear to the sleeve, potentially causing an electric shock to users. The instructions supplied with this sample were considered to be inadequate as they did not contain adequate safety information and details to ensure the correct and safe use of the product.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

Corrective action

The import has been rejected at the border.

Additional information

PSD case number: 2207-0049

Notified by: Local Authority Trading Standards

Updates to this page

Published 21 July 2022