Product Recall: Tycolit C10F6 Floodlight

Product Recall for Tycolit C10F6 Floodlight presenting a serious risk of electric shock.

Summary

Product: Tycolit C10F6 Floodlight

Hazard: The product presents a serious risk of electric shock as it was found to be inadequately earthed, meaning that if a fault was to occur, the product could become live and give the user an electric shock.

Corrective action: Import rejected at the border. Update: 02 May 2023: The product has been recalled from end users by Super Smart Services.

Product information

Type Electrical appliances and equipment - Floodlight
Brand Tycolit
Model Number C10F6
Batch Number WRD36WRGBCCT
Carton numbers TD 56 UK, RVG759-220414-0001-766, G759-ZT0000909
Country of Origin China
Product Description A black, rectangular LED Floodlight with a black metal stand
Product Report and Image Link to Product Image and PDF

Hazard

The product presents a serious risk of electric shock as it was found to be inadequately earthed, meaning that if a fault was to occur, the product could become live and give the user an electric shock. The clamping means are not adequately secured against accidental loosening and the terminal had not been tightened. The connection between the earthing terminal and earthed metal parts exceeded the 0.5 Ω limit. The conductors on the supply cord were also deemed inadequate as the cross-sectional area was found to be 0.536 mm², less than the required 1.0 mm².

Also, PVC insulated external wiring should not be used outside, however, the accompanying information indicated that the floodlight could be used outdoors. Furthermore, the instructions did not contain adequate safety information and details to ensure the correct and safe use of the product.

The product was also missing some of the required documentation and markings and does not comply with the Electrical Equipment (Safety) Regulations 2016.

Corrective action

Import rejected at the border.

Update: 02 May 2023: The product has been recalled from end users by Super Smart Services.

Additional information

PSD case number: 2212-0198, 2206-0074 and 2306-0145

Notified by: Local Authority Trading Standards

Updates to this page

Published 6 March 2023
Last updated 10 July 2023 + show all updates
  1. Additional PSD case reference number added, following an import being rejected at the border.

  2. First published.