Performance of the OptiMAL dipstick in the diagnosis of malaria infection in pregnancy
Abstract
The accuracy of OptiMAL® dipsticks was compared with that of microscopy in the diagnosis of malaria infection in pregnancy. During the course of a clinical trial of antimalarial drugs in pregnancy, we screened 4500 pregnant women of all parities who accessed antenatal clinic services at St. Theresa’s Hospital’s in Nkoranza, Ghana, between March 2003 and December 2004 with OptiMAL® dipsticks and confirmed the diagnosis of malaria with microscopy. We determined the sensitivity, specificity, positive and negative predictive values, and the area under receiver operating characteristic (ROC) curve for the OptiMAL® antigen test compared to microscopy for the diagnosis of malaria infection in pregnancy. OptiMAL® dipsticks had a sensitivity of 96.6%, specificity of 85.4%, a positive predictive value of 92.7%, a negative predictive value of 92.6%, and an area under the ROC curve of 0.91 (95% CI of 0.90–0.92). The diagnostic accuracy of the OptiMAL® dipstick is high and the test may have practical use in the diagnosis of malaria infection in pregnancy in malaria endemic countries.
Citation
Therapeutics and Clinical Risk Management (2008) 4 (3) 631-636
Links
Performance of the OptiMAL dipstick in the diagnosis of malaria infection in pregnancy